Table #1: PULSTAR Irradiation and Beamport Experimental Facilities
|
Facility |
Description |
Intensity |
Rotating Exposure Ports 4 in-pool, ex-core |
2.5” ID wet sample irradiation terminus |
1.0×1013 thermal n/cm2/sec 1.0×1012 fast n/cm2/sec |
Dry Exposure Ports 2 in-pool, ex-core |
1.25” ID dry sample irradiation terminus |
4.0×1012 thermal n/cm2/sec 1.0×1011 fast n/cm2/sec |
Pneumatic Terminus 1 in-pool, ex-core |
1.25” ID fast rabbit sample transfer system |
1.0×1013 thermal n/cm2/sec 1.0×1012 fast n/cm2/sec |
Pool Standpipes 4 in-pool, ex-core |
3.5” ID dry sample irradiation positions |
1.0×1011 thermal n/cm2/sec 5.0×109 fast n/cm2/sec |
Beamport #1 |
6-in. diameter radial tube |
1.0×1012 thermal n/cm2/sec at core end |
Beamport #2 |
6-in. diameter tangential ‘through’ tube |
1.0×1012 thermal n/cm2/sec at centerpoint |
Beamport #3 |
8-in. diameter radial tube |
1.0×1012 thermal n/cm2/sec at core end |
BP#4: Neutron Powder Diffraction Facility |
6-in. diameter radial tube |
~0.5×105 1.4Å n/cm2/sec on target |
BP#5: Neutron Imaging Facility |
6-in. diameter radial tube |
~5.0×106 thermal n/cm2/sec at 6.5 meter imaging plane |
BP#6: Intense Positron Source Facility |
12 in. by 12 in. sq. radial tube |
5-6×108 positrons/second at target; beam spot diameter is 25 mm; e+ energy variable up to 30 keV |
Thermal Column: Ultra-Cold Neutron Source Facility |
5’x5’x7’ cavity in biologic shield adjacent to reactor core |
Projected intensity of 6 to 16 million UCN’s per second |